identiFINDER R700 Backpack Radiation Detector (BRD)

The FLIR identiFINDER R700 Backpack Radiation Detector (BRD) offers new spectroscopic broad-search capabilities.

Once dismounted, the identiFINDER R700 provides the capabilities required to successfully perform wide-area searches quickly and efficiently while offering exceptional sensitivity, communication, and trusted spectroscopic algorithms in a lightweight, ergonomic form-factor.

Interrogate and isolate radiological threats quickly 

Building on the award-winning identiFINDER R440, the identiFINDER R700 offers advanced spectroscopic algorithm and detection techniques scaled to a man-portable backpack for increased sensitivity and speed.

Deploy at the scene or on the move, covertly

The identiFINDER R700 can be configured as a nondescript backpack or a stationary screening device, allowing for multiple mission sets from covert wide-area searches to temporarily checkpoints.

Share intelligence broadly, or operate silently 

Providing critical information to decision makers quickly is essential, so the identiFINDER R700 provides the capability to do so in real-time and on demand. Wireless communications and a robust API enable integration with user-deployed networks. Tethered-display options provide a radio silent (air-gapped) option for highly sensitive missions.

identiFINDER R700 Backpack Radiation Detector (BRD) features 

  • Advanced spectroscopic algorithm and detection techniques scaled to a man-portable backpack for increased sensitivity and speed
  • Can be configured as a nondescript backpack or a stationary screening device
  • Wireless communications and a robust API enable integration with user-deployed networks.

identiFINDER R700 Backpack Radiation Detector (BRD) specifications 

System Overview

Technology Backpack Radiation Detector (BRD)
Threats Detects gamma and/or neutron radiation emitted from naturaloccurrences in the environment, special nuclear material,industrial, or medical material

Technology

Detector 2 x 4 x 8” NaIL™ (NaI:Tl, Li) gamma-neutronor 2 x 4 x 8” NaI(Tl) gamma-neutron indication
Typical Resolution  ≤8.5% FWHM at 662 keV (20 °C)
Stabilization Sourceless “Quantum gain” stabilization (patents pending)
Energy Range [Gamma] 10 keV to 10 MeV (All detectors)
Dose rate range (Cs-137) 0.001 mrem/h - 10 rem/h (0.01 - 100,000 μSv/h)
Dose rate range ID mode(Cs-137) 0.001 - 0.5 mrem/h (0.01 - 5 μSv/h)
Dose rate overloadrange (Cs-137) 0.002 - 10 rem/h (20 - 100,000 μSv/h)
Gamma Sensitivity (Cs-137) 165,000 cps/mrem/h (16,500 cps/uSv/h)
Neutron Sensitivity 90 cps/nv
Linearization Real-time linearization of gamma energy
Service Interval 5 year factory maintenance recommended, not required
Standards Compliance ANSI N42.53 BRD standard fully compliantANSI N42.42 data format fully compliantIEC 62694 backpack standard fully complianceIEC 62706 BRD environmental compliantIEC 62755 data format fully compliant

 To view the full spec sheet, visit the identiFINDER R700 downloads section here.